Lander wall
Overview
- Direct light luminaire designed for use with LED light sources.
- Comprises body and optical compartment.
- Body in extruded aluminium with steel ground/wall mounting base strip.
- Optical compartment and glass holder frame in die-cast aluminium. clear sodium-calcium tempered
- Sealing glass, 5 mm thick with black screen-printing Comfort prismatic glass with black screen printing for the wall version.
- Body and optical compartment undergo multi-step pre-treatment (degreasing, fluoro-zirconium, sealing). The subsequent painting stage involves primer and liquid acrylic paint to ensure high resistance to atmospheric agents and UV rays.
- Optical compartment complete with electronic power supply and output power supply cable.
- Asymmetrical Longitudinal (AL) and Crossways (AT) optics with Opti-smart reflectors in super-pure aluminium coated with silvery deposits ensuring high efficiency and uniform light distribution.
- Replaceable LED and power supplies.
- Wall versions with transparent glass for direct and indirect high performance lighting and prismatic comfort glass for direct lighting.
- Overvoltage protection: 4kV in Common Mode (CM), 2kV in Differential Mode (DM).
- The SPD accessory (JAL6) increases overvoltage protection to 10kV/10kV (CM/DM).
- Contact temperature <45°.
- Application ambient temperature: -30°C +50°C
- All screws used are in A2 stainless steel.
- Dark Sky Approved: the IDA’s Fixture Seal of Approval programme certifies outdoor lighting fixtures as being Dark Sky friendly, so in compliance with the following:
- Maximum Correlated Color Temperature of 3000K.
- Up-light allowance limited to 0.5% of total output, or 50 lumens, with no more than10 lumens in the 90-100 degree UL zone.
- Luminaires are required to have fixed mounting to ensure they are installed as tested; there can be up to + or - 10° adjustment for levelling if needed.
- Luminaires must have dimming capability to 10% full rating.
- In order to be compliant with the requirements of DarkSky Approved programs, the Lander Wall version must be installed with the light emission downward.
Protection Ratings
-
Class II -
IP66
Mechanical Resistance
-
Protected against 10 J shocks
Certifications & Approvals
-
BVB Byggvarube- dömningen -
CCC Pending -
CCC S&E -
CE -
ENEC-03 -
UK Conformity Assessed -
BIS -
QCERT
Key Features
-
Opti Smart -
No upward emission of the light flow -
Suitable for extreme conditions -
Pass-through wiring -
F Mark